SCADA Setup: Alarms and Notifications Configuration

In SCADA (Supervisory Control and Data Acquisition) systems, alarms and notifications play a critical role in detecting anomalies, preventing equipment failure, and ensuring operational safety. Proper alarm management allows operators to quickly respond to faults, minimize downtime, and optimize industrial processes.

SCADA system alarms and configuration infographic with operators, control room, and digital alarming visuals
SCADA alarm setup and control system visualization

What are Alarms and Notifications in SCADA?

Alarms and notifications in SCADA are used to alert operators when a process variable exceeds a predefined threshold or when an unexpected event occurs.

Types of SCADA Alarms:

  • Digital Alarms: Triggered by binary states (e.g., Motor ON/OFF, Door OPEN/CLOSED).
  • Analog Alarms: Triggered when process variables exceed a setpoint (e.g., Temperature > 120°C).
  • Rate-of-Change Alarms: Activated when a variable changes too quickly (e.g., Pressure drop > 10 PSI in 5 seconds).
  • System Alarms: Detect communication failures, power outages, or security breaches.

Key Features of SCADA Notifications:

  • Visual Alerts: Flashing indicators or color-coded warnings.
  • Audible Alerts: Sirens or beeping sounds for critical alarms.
  • Remote Notifications: SMS, Email, or App-based alerts for offsite monitoring.
  • Event Logging: Automatic storage of alarm history for future analysis.

Steps to Configure Alarms and Notifications in SCADA

1. Define Alarm Parameters

Set alarm conditions based on critical process values.

Example Threshold Settings:

Alarm NameTrigger ConditionPriorityNotification Method
High_TempTemperature > 120°CCriticalSMS + Email
Low_PressurePressure < 5 PSIWarningVisual + Sound
Power_FailureNo power detectedCriticalMobile App Alert

2. Categorize Alarms by Priority

SCADA alarms should be grouped based on urgency to help operators prioritize responses.

Alarm Categories:

  • Critical Alarms: Require immediate attention (e.g., equipment failure, system shutdown).
  • Warning Alarms: Alert operators of abnormal trends (e.g., slow pressure loss).
  • Informational Alarms: Log non-urgent events (e.g., operator login, maintenance reminders).

Best Practices:

  • Assign color codes (Red for critical, Yellow for warning).
  • Display alarms in order of importance on the HMI.
  • Ensure high-priority alarms trigger multiple notifications (visual, sound, SMS).

3. Configure Alarm Display in HMI

HMI screens should provide a clear view of active alarms and allow operators to acknowledge and resolve issues.

Recommended HMI Alarm Design:

  • Use blinking icons for active alarms.
  • Include alarm descriptions instead of just error codes.
  • Add real-time timestamping to track when alarms occur.
  • Provide an acknowledge button for each alarm to confirm operator action.

Example HMI Alarm Screen:

  • 📌 Tank Overflow! [🔴 Critical] (Acknowledge)
  • 📌 Low Flow Rate [🟡 Warning] (Investigate)
  • 📌 Operator Login Successful [🔵 Info]

4. Set Up Remote Notifications

Operators should receive instant alerts on critical failures, even when offsite.

Common Notification Methods:

  • SMS Alerts: Sends text messages for emergency conditions.
  • Email Notifications: Provides alarm logs for reporting.
  • Push Notifications: Mobile apps trigger alerts for faster response.
  • Voice Call Alerts: Used in high-risk industries for urgent failures.

Example:

🚨 Critical Alert: Boiler Pressure Exceeds Safe Limit (150 PSI)!
📩 Sent to Operator John (SMS, Email) at 03:45 PM.

5. Implement Alarm Logging and Reports

All alarms should be stored for historical analysis and troubleshooting.

Key Features of Alarm Logging:

  • Timestamp of each alarm.
  • Operator action taken (Acknowledged, Resolved).
  • Frequency of recurring issues.
  • Downtime tracking due to alarm conditions.

Example Alarm Report:

Date & TimeAlarm NameStatusOperator Response
02/10/2025 - 10:05 AMHigh_TempResolvedReduced Boiler Temperature
02/10/2025 - 11:30 AMLow_PressureActiveMaintenance Notified

📊 SCADA analytics can use this data to identify problem areas and optimize processes.

Best Practices for SCADA Alarm Configuration

  • Avoid Alarm Flooding: Reduce unnecessary alarms to prevent operator fatigue.
  • Use Clear Descriptions: Instead of "Error 1023," display "Pump 3: Overheating - 135°C."
  • Enable Alarm Shelving: Temporarily disable non-critical alarms while focusing on urgent ones.
  • Ensure Redundancy: Use multiple notification channels (SMS + Email + Dashboard) for critical alerts.
  • Conduct Regular Testing: Simulate alarm conditions to ensure correct triggers and responses.

Industry Use Cases

1. Water Treatment Plant

🔹 SCADA Application: Alarms for low water levels and chlorine imbalances.
🔹 Impact: Reduced water wastage and improved compliance with health standards.

2. Oil and Gas Pipeline Monitoring

🔹 SCADA Application: Leak detection and pressure monitoring alarms.
🔹 Impact: Prevented hazardous leaks, reducing environmental risks.

3. Power Grid Management

🔹 SCADA Application: Fault detection in transformers and substations.
🔹 Impact: Improved response time, minimizing electricity outages.

Alarms and notifications are essential for effective SCADA operations, ensuring operators can respond to critical situations promptly. A well-structured alarm system improves safety, enhances efficiency, and minimizes downtime. By categorizing alarms, configuring remote alerts, and maintaining logs, industries can optimize their SCADA system for maximum reliability and performance.